DocumentCode
2656945
Title
Air-cooled trim dipoles for the Fermilab Main Injector
Author
Harding, D.J. ; Carson, J.A. ; Chester, N.S. ; Garvey, J.D. ; Krafczyk, G.E. ; Makarov, A. ; Terechkine, I. ; Yarba, V.A.
Author_Institution
Fermi Nat. Accel. Lab., Batavia, IL, USA
Volume
3
fYear
1997
fDate
12-16 May 1997
Firstpage
3291
Abstract
New horizontal and vertical trim dipoles have been designed for the Fermilab Main Injector (FMI) and are being assembled in the Fermilab Technical Division. Magnets are 42.6 cm in length (30.5 cm steel length) and have similar cross-section dimensions. The horizontal (vertical) magnet gap is 50.8 mm (127 mm) and the target integrated strength is 0.072 T*m (0.029 T*m). The major design effort lay in making air cooling possible for these magnets. This report presents the magnets´ thermal and magnetic properties and discusses the limitation on excitation current
Keywords
accelerator magnets; booster injectors; electromagnets; proton accelerators; synchrotrons; 30.5 cm; 42.6 cm; Fermilab Main Injector; air-cooled trim dipoles; horizontal magnet gap; horizontal trim dipoles; target integrated strength; vertical magnet gap; vertical trim dipoles; Assembly; Coils; Fixtures; Lamination; Magnetic cores; Magnetic field measurement; Magnets; Stacking; Steel; Temperature;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1997. Proceedings of the 1997
Conference_Location
Vancouver, BC
Print_ISBN
0-7803-4376-X
Type
conf
DOI
10.1109/PAC.1997.753185