• DocumentCode
    2657584
  • Title

    Magnetic design of a high gradient quadrupole for the LHC low-β insertions

  • Author

    Sabbi, G. ; Gourlay, S.A. ; Kerby, J. ; Lamm, M.J. ; Limon, P.J. ; Nobrega, F. ; Novitski, I. ; Strait, J.B. ; Zlobin, A.V. ; Caspi, S. ; Scanlan, R. ; Ghosh, A. ; Gupta, R.

  • Author_Institution
    Fermi Nat. Accel. Lab., Batavia, IL, USA
  • Volume
    3
  • fYear
    1997
  • fDate
    12-16 May 1997
  • Firstpage
    3398
  • Abstract
    Fermilab, Lawrence Berkeley National Laboratory and Brookhaven National Laboratory have formed a consortium to provide components for the Large Hadron Collider (LHC) to be built at CERN. The U.S. contribution includes half of the high gradient quadrupoles (HGQ) for the inner focusing triplets. In this paper a description of the HGQ magnetic design is given, including short sample limit for field gradient, sources and expected values of systematic and random field errors, and possible strategies for field quality correction
  • Keywords
    accelerator magnets; colliding beam accelerators; proton accelerators; storage rings; superconducting magnets; synchrotrons; LHC low-beta insertions; Large Hadron Collider; field gradient; field quality correction; high gradient quadrupole; inner focusing triplets; magnetic design; random field errors; Cables; Laboratories; Lamination; Large Hadron Collider; Niobium compounds; Steel; Structural beams; Superconducting coils; Superconducting magnets; Titanium compounds;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1997. Proceedings of the 1997
  • Conference_Location
    Vancouver, BC
  • Print_ISBN
    0-7803-4376-X
  • Type

    conf

  • DOI
    10.1109/PAC.1997.753221
  • Filename
    753221