DocumentCode
2670910
Title
Research on global fuzzy control method over reactor power
Author
Kecheng, Wang
Author_Institution
Sci. & Technol. on Reactor Syst. Design Technol. Lab., Chengdu, China
fYear
2012
fDate
23-25 May 2012
Firstpage
2144
Lastpage
2146
Abstract
Among reactor power control methods, the most commonly used one is Proportional-Integral-Derivative (PID) control method, though it is very easy to carry out, the disadvantage of this method is that the control speed is slow and the overshoot is large. Fuzzy control method of reactor power can ameliorate the PID method, but not all of them performances effective enough. After analyzing the reason why the control speed was so slow and why the large overshoot occurred under load drop working condition, this paper tabled a new method to control the reactor power - the global fuzzy control method, then control simulation was made on the reactor coolant system simulation platform. The simulation results showed that the global fuzzy control method controlled fast and had a small overshoot under load drop working condition, and almost didn´t influence the steady-state error.
Keywords
fission reactor coolants; fuzzy control; physical instrumentation control; power control; control simulation; control speed; global fuzzy control method; load drop working condition; overshoot; reactor coolant system simulation platform; reactor power control methods; steady-state error; Employee welfare; Fuzzy control; Inductors; PD control; Power control; Temperature control; Temperature measurement; global fuzzy control; power control; reactor; simulation;
fLanguage
English
Publisher
ieee
Conference_Titel
Control and Decision Conference (CCDC), 2012 24th Chinese
Conference_Location
Taiyuan
Print_ISBN
978-1-4577-2073-4
Type
conf
DOI
10.1109/CCDC.2012.6244343
Filename
6244343
Link To Document