• DocumentCode
    2684964
  • Title

    Evaluation of SAR in human tissue at 5-6 GHz

  • Author

    Penney, Christopher W. ; Luebbers, Raymond J.

  • Author_Institution
    Remcom Inc., State College, PA, USA
  • fYear
    2005
  • fDate
    3-8 July 2005
  • Firstpage
    776
  • Abstract
    High resolution human body meshes developed from visible human male data set were used to evaluated specific absorption rate (SAR) in the 5 to 6 GHz range applicable to wireless fidelity (WiFi) devices. The focus of the study was to determine exposure in the thigh and torso region of the body caused by radiating devices such as wireless network adaptors on laptop computers. The goal was to determine if any homogeneous liquid would consistently provide a more conservative measure of SAR for the cases in question so such a liquid could be used for experimental testing.
  • Keywords
    biological effects of fields; biological tissues; electromagnetic wave absorption; laptop computers; microwave propagation; wireless LAN; 5 to 6 GHz; SAR; WiFi devices; experimental testing; high resolution human body meshes; homogeneous liquid; human tissue; laptop computers; radiating devices; specific absorption rate; thigh exposure; torso exposure; visible human male data set; wireless fidelity devices; wireless network adaptors; Biological system modeling; Frequency; Geometry; Humans; Liquids; Medical simulation; Skin; Testing; Thigh; Torso;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Antennas and Propagation Society International Symposium, 2005 IEEE
  • Print_ISBN
    0-7803-8883-6
  • Type

    conf

  • DOI
    10.1109/APS.2005.1552132
  • Filename
    1552132