DocumentCode
2685027
Title
Session 26: Developments in the Six-Port Technique of Microwave Measurement
Author
Engen, G.F.
fYear
1984
fDate
May 30 1984-June 1 1984
Firstpage
563
Lastpage
563
Abstract
In the field of microwave metrology, interest continues to focus on the dual six-port automatic network analyzer, and refinements of it. While the technique is demonstrably capable of unprecedented accuracy, the realization of this performance potential requires a signal source which is both "cleaner" (free from harmonics, etc.) and of higher power (by 10-20 dB.) than required by other network analyzers. In addition, and for the most part, the existing six-port systems fail to provide a real time display, although some interesting results in this area have been reported in England.
Keywords
Calibration; Displays; Harmonic analysis; Metrology; Microwave measurements; Microwave theory and techniques; NIST; Performance analysis; Power system harmonics; Signal analysis;
fLanguage
English
Publisher
ieee
Conference_Titel
Microwave Symposium Digest, 1984 IEEE MTT-S International
Conference_Location
San Francisco, CA, USA
ISSN
0149-645X
Type
conf
DOI
10.1109/MWSYM.1984.1131863
Filename
1131863
Link To Document