• DocumentCode
    2688668
  • Title

    Surface contact of bound targeted microbubbles

  • Author

    Kooiman, K. ; Kokhuis, Tom J. A. ; Skachkov, I. ; Bosch, Johan G. ; van der Steen, Anton F. W. ; van Cappellen, W.A. ; de Jong, Nico

  • Author_Institution
    Dept. of Biomed. Eng., Erasmus MC, Rotterdam, Netherlands
  • fYear
    2012
  • fDate
    7-10 Oct. 2012
  • Firstpage
    2161
  • Lastpage
    2163
  • Abstract
    For molecular imaging using ultrasound contrast agents, targeted microbubbles are designed with specific ligands linked to the coated shell. Research is ongoing to determine the binding force of targeted microbubbles and to distinguish bound from unbound targeted microbubbles using ultrasound. For this, the actual surface of the targeted microbubbles that binds to a pathology is important. This study focuses on determining the surface contact of bound targeted microbubbles by fluorescence microscopy. Biotinylated lipid-coated microbubbles (3-7 μm in diameter) with either DSPC or DPPC as the main lipid were targeted to a streptavidin-coated surface. The binding area of targeted microbubbles was found to be 6 ± 4% of the total microbubble surface for microbubbles with DSPC as the main lipid (n=22) and 11 ± 4% for microbubbles with DPPC as the main lipid (n=24). The difference can be explained by the heterogeneous distribution of the ligand for DSPC microbubbles whereas the ligand is homogeneously distributed for DPPC microbubbles. These findings can be used to improve the binding of targeted microbubbles and for the ongoing research to distinguish bound from unbound microbubbles.
  • Keywords
    biomedical materials; biomedical optical imaging; biomedical ultrasonics; bonds (chemical); bubbles; fluorescence; microfluidics; molecular biophysics; optical microscopy; organic compounds; DPPC main lipid; DSPC main lipid; biotinylated lipid-coated microbubble; bound targeted microbubble surface contact; coated shell ligand; fluorescence microscopy; heterogeneous ligand distribution; homogeneous ligand distribution; molecular imaging; pathology; size 3 mum to 7 mum; streptavidin-coated surface; surface contact determination; targeted microbubble binding area; targeted microbubble binding force; targeted microbubble bond; targeted microbubble design; ultrasound contrast agent; unbound targeted microbubble; Coatings; Fluorescence; Lipidomics; Molecular imaging; Surface treatment; Ultrasonic imaging; ligand distribution; molecular imaging; surface contact; targeted microbubbles; ultrasound contrast agent;
  • fLanguage
    English