DocumentCode
2688721
Title
On the accuracy specifications of Phasor Measurement Units
Author
Lixia, Marco ; Muscas, Carlo ; Sulis, Sara
Author_Institution
Dept. of Electr. & Electron. Eng., Univ. of Cagliari, Cagliari, Italy
fYear
2010
fDate
3-6 May 2010
Firstpage
1435
Lastpage
1440
Abstract
A critical overview of the accuracy specifications of Phasor Measurement Units in the measurement of synchrophasors is presented in this work. The focus is both on the possible ambiguity arising from the definition of Total Vector Error (TVE), provided by the IEEE Standard C37.118-2005, and on the lack of homogeneity in the information provided by PMU manufacturers, that makes a very difficult task the comparison of the performance ensured by the different commercial devices. The discussion is based on both theoretical considerations and experimental results on PMU prototypes.
Keywords
phase measurement; IEEE Standard C37.118-2005; PMU manufacturers; phasor measurement units; synchrophasors; total vector error; Area measurement; Frequency synchronization; Instruments; Manufacturing; Measurement standards; Phasor measurement units; Power system dynamics; Power system protection; Testing; Time measurement; Accuracy; IEEE Standard C37.118-2005; Phasor Measurement Unit; Synchronization; Synchrophasor; Total Vector Error; Wide Area Monitoring System;
fLanguage
English
Publisher
ieee
Conference_Titel
Instrumentation and Measurement Technology Conference (I2MTC), 2010 IEEE
Conference_Location
Austin, TX
ISSN
1091-5281
Print_ISBN
978-1-4244-2832-8
Electronic_ISBN
1091-5281
Type
conf
DOI
10.1109/IMTC.2010.5488172
Filename
5488172
Link To Document