• DocumentCode
    2688933
  • Title

    In-situ observation on electrochemical migration of lead-free solder joints under water drop test

  • Author

    Xia, Y.H. ; Jillek, W. ; Schmitt, E.

  • Author_Institution
    Coll. of Mech. Eng., Zhejiang Univ. of Technol., Hangzhou
  • fYear
    2008
  • fDate
    28-31 July 2008
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    Electrochemical migration (ECM) of lead-free solder joints were investigated by water drop test method. Nine types solder pastes were employed to compare the ECM susceptible. The effects of applied voltage, electrodes spacing and flux residue on the ECM were in-situ observed. The microstructure and composition of the growing dendrites during ECM were detected. The results revealed that higher voltage and narrower spacing weakened the ECM reliability of solder joints. The flux residua inhibited the occurrence of ECM. The main migration element was Pb in Pb-bearing solder joints. For Sn-Ag-Cu solder joints, it was Sn and Cu to migrate during the ECM process. Zn was the only migration element in the SnZnBi solder joint. Sn-Zn-Bi solder exhibited the best ECM reliability.
  • Keywords
    bismuth alloys; copper alloys; dendrites; electromigration; silver alloys; solders; tin alloys; zinc alloys; SnAgCu; SnZnBi; dendrites; electrochemical migration; flux residua; lead-free solder joints; microstructure; reliability; water drop test method; Electrochemical machining; Electrodes; Environmentally friendly manufacturing techniques; Lead; Microstructure; Soldering; Testing; Tin; Voltage; Zinc;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electronic Packaging Technology & High Density Packaging, 2008. ICEPT-HDP 2008. International Conference on
  • Conference_Location
    Shanghai
  • Print_ISBN
    978-1-4244-2739-0
  • Electronic_ISBN
    978-1-4244-2740-6
  • Type

    conf

  • DOI
    10.1109/ICEPT.2008.4607147
  • Filename
    4607147