DocumentCode
2694173
Title
Shielding effectiveness-measurement and analysis
Author
Sharma, K. ; Chand, Sulekh ; Yadav, Rajni
Author_Institution
Electron. Regional Test Lab., New Delhi, India
fYear
1997
fDate
3-5 Dec 1997
Firstpage
3
Lastpage
6
Abstract
Shielded chambers are used in order to obtain a “secluded environment” in terms of RF interference. The placement of filters and waveguides along with openings like doors, windows and cabling layout have a considerable deteriorating effect on shielding. The effectiveness of the chamber selection of filter is based on power handling capacity, attenuation characteristics and ease of grounding with respect to the chamber. Ferrites are used for suppression of unwanted signals. The focus of this paper is to describe on site shielding effectiveness measurement experiences. The deteriorating effects of the improper installation of filters, wire layout and other construction aspects have also been discussed
Keywords
electromagnetic shielding; interference suppression; radiofrequency interference; test facilities; RF interference; attenuation characteristics; cabling layout; construction aspects; doors; ferrites; filters; grounding; power handling capacity; shielded chambers; shielding effectiveness; site shielding effectiveness measurement; suppression; waveguides; windows; wire layout; Circuit testing; Electronic equipment testing; Electronics industry; Fasteners; Hafnium; Industrial electronics; Interference; Iron; Radio frequency; Utility programs;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Interference and Compatibility '97. Proceedings of the International Conference on
Conference_Location
Hyderabad
Print_ISBN
81-900652-0-3
Type
conf
DOI
10.1109/ICEMIC.1997.669747
Filename
669747
Link To Document