  • Abstract
    This paper deals with the identification of the flux for a system of conservation laws in the specific example of analytic chromatography. The fundamental equations of chromatographic process are highly non linear. The state-of-the-art evolution strategy, CMA-ES (the covariance matrix adaptation evolution strategy), is used to identify the parameters of the so-called isotherm function. The approach was validated on different configurations of simulated data using either one, two or three components mixtures. CMA-ES is then applied to real data cases and its results are compared to those of a gradient-based strategy.
  • Keywords
    chromatography; covariance matrices; gradient methods; isothermal transformations; CMA-ES; chromatography; conservation laws; covariance matrix adaptation evolution strategy; gradient-based strategy; isotherm function; Absorption; Chemical industry; Covariance matrix; Inverse problems; Numerical simulation; Parametric statistics; Partial differential equations; Petroleum industry; Pharmaceuticals; Solid modeling;