DocumentCode
2707563
Title
Estimation of synchronous machine parameter by standstill frequency response tests
Author
Hasni, M. ; Touhami, O. ; Ibtiouen, Rachid ; Fadel, Maurice ; Caux, Stephane
Author_Institution
Lab. de Rech. en Electrotech., Ecole Nat. Polytech., Algiers
fYear
2008
fDate
21-24 April 2008
Firstpage
1
Lastpage
6
Abstract
This paper presents the identification of the linear parameters of a salient-pole synchronous machine at standstill by frequency response tests data (SSFR). The procedure consists in defining and conducting the frequency response tests, identifying the model structure, estimating the machine parameters. The parameters of operational impedances or in other terms, the reactances and the time constants are estimated. The obtained results are presented from tests on the synchronous machine of 1,5 kVA/380 V/1500 rpm.
Keywords
frequency response; machine testing; parameter estimation; synchronous machines; SSFR; apparent power 1.5 kVA; linear parameter identification; salient-pole synchronous machine; standstill frequency response test; voltage 380 V; Circuit testing; Damping; Equations; Frequency estimation; Frequency response; Machine windings; Parameter estimation; Stability; Synchronous machines; Voltage; Parameter Estimation; Standstill Test Frequency Responses; Synchronous Machine;
fLanguage
English
Publisher
ieee
Conference_Titel
Industrial Technology, 2008. ICIT 2008. IEEE International Conference on
Conference_Location
Chengdu
Print_ISBN
978-1-4244-1705-6
Electronic_ISBN
978-1-4244-1706-3
Type
conf
DOI
10.1109/ICIT.2008.4608544
Filename
4608544
Link To Document