DocumentCode
2724394
Title
Monitoring of the Ultrasonic Wire Bonding Quality Based on System Impedance
Author
Feng, Wuwei ; Zhang, Yulian ; Meng, Qingfeng
Author_Institution
Sch. of Mech. & Electr. Eng., Zhejiang Ocean Univ., ZhouShan, China
fYear
2012
fDate
11-13 Aug. 2012
Firstpage
2013
Lastpage
2016
Abstract
A new method is putted forward to monitor online wire bonding quality through monitoring the change of system input electrical impedance. The signals of voltage and current of ultrasonic piezoelectric driver are transformed analytic signals by Hilbert transform. Using these analytic signals, the input electrical impedance is acquired. There are significant changes in the system input electrical impedance. Good correlation is found between the change in system input electrical impedance and the bonding intensity. A neural network module is constructed to classify and identify bonding quality. The results evaluated are uniform basically with the destructed shear test experiment. Bonding process drift towards unacceptable bond quality can be identified. The work will be used to develop a real-time monitoring system for ultrasonic wire bonding.
Keywords
electronic engineering computing; lead bonding; neural nets; piezoelectric devices; ultrasonic bonding; Hilbert transform; destructed shear test experiment; electrical impedance; neural network module; system impedance; ultrasonic piezoelectric driver; ultrasonic wire bonding quality monitoring; Acoustics; Bonding; Impedance; Monitoring; Vibrations; Wires; Bonding quality; Impedance; Neural network; Real-time monitoring; Ultrasonic wire bonding;
fLanguage
English
Publisher
ieee
Conference_Titel
Computer Science & Service System (CSSS), 2012 International Conference on
Conference_Location
Nanjing
Print_ISBN
978-1-4673-0721-5
Type
conf
DOI
10.1109/CSSS.2012.501
Filename
6394819
Link To Document