• DocumentCode
    2740514
  • Title

    Characterization of SET response of the LM124A the LM111, and the LM6144

  • Author

    Savage, M.W. ; Turflinger, T. ; Titus, J.L. ; Pease, R.L. ; Poivey, C.

  • Author_Institution
    NAVSEA Surface Warfare Center Div., Crane, IN, USA
  • fYear
    2003
  • fDate
    21-25 July 2003
  • Firstpage
    121
  • Lastpage
    126
  • Abstract
    We present a paper that characterizes the single event transient response of the LM124, LM111, and LM6144 in a heavy ion environment. In the paper both the test methods used and the data are presented.
  • Keywords
    ion beam effects; operational amplifiers; transient response; LM111; LM124A; LM6144; SET response; device under test; heavy ion environment; operational amplifier; single event transient; test circuit; voltage reference; Circuit testing; FETs; Operational amplifiers; Probes; Pulse amplifiers; Pulse shaping methods; Relays; Senior members; Shape; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Radiation Effects Data Workshop, 2003. IEEE
  • Print_ISBN
    0-7803-8127-0
  • Type

    conf

  • DOI
    10.1109/REDW.2003.1281361
  • Filename
    1281361