DocumentCode
2748128
Title
A current transformer test set for the audio frequency range
Author
Mohns, E. ; Yue, C. ; Zhou, F. ; Möhring, T. ; Schmidt, M.
Author_Institution
Phys.-Tech. Bundesanstalt (PTB), Braunschweig, Germany
fYear
2012
fDate
1-6 July 2012
Firstpage
302
Lastpage
303
Abstract
This paper describes the setup of a test set for current transformer (CTTS) calibrations using a two-channel voltage ratio measurement method. A wideband two-channel digitizer and a differential analogue front-end are used as the heart of the ratio measurement system. The front-end suppresses some static errors of the digitizer and is tested for the frequency range up to 200 kHz. Various active or passive shunts adapt the secondary output current to the ± 2 V or ± 10 V input range of the ratio measurement system. Furthermore, the system is used to set up future measurement systems for efficiency measurements in the frame of current European Metrology Programmes (EMRP).
Keywords
current transformers; differential amplifiers; measurement errors; voltage measurement; European Metrology Programmes; audio frequency range; current transformer test set; differential analogue front-end; efficiency measurements; frequency 200 kHz; secondary output current; static errors; two-channel voltage ratio measurement method; wideband two-channel digitizer; Current measurement; Current transformers; Europe; Frequency measurement; Measurement uncertainty; Voltage measurement; Wideband; bridge; current transformers; differential amplifiers; voltage ratio;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements (CPEM), 2012 Conference on
Conference_Location
Washington, DC
ISSN
0589-1485
Print_ISBN
978-1-4673-0439-9
Type
conf
DOI
10.1109/CPEM.2012.6250922
Filename
6250922
Link To Document