• DocumentCode
    2750484
  • Title

    The analysis of attenuation characteristics for HEMP passing through the air-tight door

  • Author

    Liu Yi-ping ; Zhou Bi-hua

  • Author_Institution
    EMP Lab., Nanjing Eng. Inst., China
  • fYear
    2003
  • fDate
    4-7 Nov. 2003
  • Firstpage
    237
  • Lastpage
    240
  • Abstract
    The attenuation characteristics of high-altitude nuclear blast electromagnetic pulse (HEMP) passing through the infinite metal board are obtained in this paper and the influence caused by aperture is analyzed synchronously. On the basis of these properties, the methods that can improve shielding efficiency (SE) are discussed by combining the application for the air-tight door then many experimental results are given.
  • Keywords
    attenuation measurement; electromagnetic pulse; electromagnetic shielding; HEMP; air-tight door; aperture influence; attenuation characteristics; infinite metal board; Apertures; Attenuation; EMP radiation effects; Electromagnetic radiation; Electromagnetic shielding; Electronic equipment; Frequency domain analysis; Laboratories; Silver; Steel;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Environmental Electromagnetics, 2003. CEEM 2003. Proceedings. Asia-Pacific Conference on
  • Conference_Location
    Hangzhou, China
  • Print_ISBN
    7-5635-0802-3
  • Type

    conf

  • DOI
    10.1109/CEEM.2003.237922
  • Filename
    1282315