• DocumentCode
    2758322
  • Title

    Use of an electronic nose to estimate paper insulation degradation

  • Author

    Lessard, M.-C. ; Noirhomme, B. ; Larocque, G. ; Vienneau, M.

  • Author_Institution
    Inst. de Rech. d´´Hydro-Quebec (IREQ), Varennes, QC, Canada
  • fYear
    2012
  • fDate
    10-13 June 2012
  • Firstpage
    350
  • Lastpage
    355
  • Abstract
    The ultimate life of a transformer primarily depends on the insulation of its active part, i.e., mainly the oil and paper complex. At present, the tools used to directly determine the state of solid insulation require transformers to be detanked in order to take paper samples for laboratory analysis. Indirect methods (oil analysis) require a complex separation system and need accurate calibration of a detector. The electronic nose technology is now widely used in different industrial areas to detect the degradation of several convenience goods like wine, coffee and cheese. Based on metal oxide semiconductor sensors from different technologies, these instruments are designed to detect odours just like a human nose. They can be set to recognize different types of degradation processes, thus serving as an efficient diagnostic tool. This original method applied to the characterization of insulation paper aging should be easier to perform than ASTM D 4243, which required the oil to be removed from the paper, dissolving it, and then measuring the degree of polymerization (DPv) by viscosimetry. This paper presents the development of a method that uses an electronic nose to determine the degree of polymerization of paper samples processed through a head space system with an automatic sampler device without having to remove the oil. Aged laboratory samples were analyzed with the electronic nose and with the standard ASTM D 4243 test method to build a calibration curve. This curve was then used to determine the DPv value of different field paper samples and compared to ASTM D 4243 results. Until now, the method developed by IREQ is reproducible and less time-consuming than the standard method currently used by Hydro-Québec, but is unfortunately less precise (20% vs. 5%). More work is needed to optimize the calibration model to potentially improve the method´s precision.
  • Keywords
    ageing; electronic noses; paper; remaining life assessment; transformer oil; DPv value; Hydro-Quebec; automatic sampler device; complex separation system; degree-of-polymerization-viscosimetry; detector calibration; diagnostic tool; electronic nose technology; head space system; indirect method; insulation paper aging characterization; metal oxide semiconductor sensors; odour detection; oil analysis; oil-paper complex; paper insulation degradation; solid insulation; standard ASTM D 4243 test method; transformer life; Aging; Calibration; Degradation; Electronic noses; Materials; Moisture; Predictive models; Electronic nose; degree of polymerization; electrical insulating paper; paper degradation; transformer;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation (ISEI), Conference Record of the 2012 IEEE International Symposium on
  • Conference_Location
    San Juan, PR
  • ISSN
    1089-084X
  • Print_ISBN
    978-1-4673-0488-7
  • Electronic_ISBN
    1089-084X
  • Type

    conf

  • DOI
    10.1109/ELINSL.2012.6251488
  • Filename
    6251488