• DocumentCode
    2772760
  • Title

    Partial discharges as a diagnostic tool for full size power capacitors

  • Author

    Hantouche, Charles

  • Author_Institution
    Direction des Etudes et Recherches, Electr. de France, Les Renardieres, France
  • Volume
    2
  • fYear
    1996
  • fDate
    16-19 Jun 1996
  • Firstpage
    505
  • Abstract
    In this paper, partial discharge (PD) measurements on industrial power capacitors have been carried out. Results of some physical parameters are presented after different accelerated aging times and during transient overvoltage tests on all-film power capacitors, with high capacitance values. Many observations emerge from the PD measurements and some parameters may indicate dielectric capacitor states
  • Keywords
    ageing; electric breakdown; insulation testing; life testing; partial discharges; power capacitors; accelerated aging; all-film power capacitors; diagnostic tool; dielectric capacitor states; full-size power capacitors; insulation breakdown testing; partial discharge measurements; transient overvoltage tests; Accelerated aging; Capacitance; Dielectric measurements; Fuels; Partial discharges; Power capacitors; Power measurement; Space vector pulse width modulation; Testing; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation, 1996., Conference Record of the 1996 IEEE International Symposium on
  • Conference_Location
    Montreal, Que.
  • ISSN
    1089-084X
  • Print_ISBN
    0-7803-3531-7
  • Type

    conf

  • DOI
    10.1109/ELINSL.1996.549393
  • Filename
    549393