DocumentCode
2774498
Title
Human exposure to pulsed current waveforms below 100 kHz
Author
Desideri, Daniele ; Maschio, Alvise ; Mattavelli, Paolo
Author_Institution
Dept. of Electr. Eng., Univ. of Padova, Padova
fYear
2008
fDate
8-12 Sept. 2008
Firstpage
1
Lastpage
6
Abstract
A tool for the analysis below 100 kHz of pulsed current waveforms with reference to human exposure has been developed. It consists of a dedicated program written in Matlab. As input data, a trapezoidal pulsed current waveform has been considered, and, varying the rise time and the duty-cycle, a parametric analysis has been performed. Also a noise superimposed to the signal has been considered. Parameters relevant to human exposure have been calculated following the ICNIRP Guidelines. A schematic operative diagram for metal inert gas welding applications is proposed; an experimental set-up has been built and the obtained results are reported.
Keywords
arc welding; biological effects of radiation; electromagnetic compatibility; human exposure; metal inert gas welding applications; pulsed current waveforms; Engineering management; Frequency; Guidelines; Humans; Magnetic analysis; Magnetic flux density; Space vector pulse width modulation; Technology management; Tin; Welding; Human exposure; MIG; pulsed current; welding;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility - EMC Europe, 2008 International Symposium on
Conference_Location
Hamburg
Print_ISBN
978-1-4244-2737-6
Electronic_ISBN
978-1-4244-2737-6
Type
conf
DOI
10.1109/EMCEUROPE.2008.4786884
Filename
4786884
Link To Document