DocumentCode
2781486
Title
On the suitability of a Two-Pulse Synthesis model for photoplethysmograph signal analysis in Public cardiac care program
Author
Goswami, Dharitri ; Chaudhuri, Koel ; Mukherjee, Jayanta
Author_Institution
Sch. of Med. Sci. & Technol., Indian Inst. of Technol., Kharagpur, India
fYear
2010
fDate
16-18 Dec. 2010
Firstpage
284
Lastpage
289
Abstract
This paper presents a non-invasive, preventive approach to measure arterial parameters by analysis of photoplethysmograph (PPG) signals. A recently proposed Two Pulse Synthesis (TPS) model [Goswami 2010a] has been used to measure pulse wave velocity (PWV) and several new parameters of normal and diseased subjects having hypertension or diabetes or both. Results, presented through tables and figures, indicate the merits of TPS model. A scheme for integration of cardiac care for rural people has been outlined. Longitudinal studies using the TPS model has also been advocated as a part of cardiac care supported by a set of experimental results.
Keywords
cardiology; diseases; haemodynamics; health care; patient care; photoplethysmography; physiological models; arterial parameters; diabetes; hypertension; photoplethysmograph signal analysis; public cardiac care program; pulse wave velocity; rural cardiac care; two-pulse synthesis model; Absorption; Argon; Cardiology; Delta modulation; Diseases; Lead; Reflection;
fLanguage
English
Publisher
ieee
Conference_Titel
Systems in Medicine and Biology (ICSMB), 2010 International Conference on
Conference_Location
Kharagpur
Print_ISBN
978-1-61284-039-0
Type
conf
DOI
10.1109/ICSMB.2010.5735388
Filename
5735388
Link To Document