• DocumentCode
    278430
  • Title

    Radiated emission measurements in screened rooms; techniques for the reduction of calibration uncertainty

  • Author

    Marvin, A.C. ; Simpson, G.

  • Author_Institution
    Dept. of Electron., York Univ., UK
  • fYear
    1991
  • fDate
    33393
  • Firstpage
    42401
  • Lastpage
    210
  • Abstract
    Describes the measurement tools, and also a preliminary calibration technique which, in favourable circumstances, enables screened room measurements in the 1-30 MHz frequency range to be used to predict free-space radiation from the simulated device under test. The technique uses the spherical dipole as a calibration device
  • Keywords
    calibration; field strength measurement; 1 to 30 MHz; HF; calibration uncertainty reduction; free-space radiation; radiated emission measurements; screened rooms; spherical dipole;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Achieving an Acceptable Confidence Level in EMC Measurements, IEE Colloquium on
  • Conference_Location
    London
  • Type

    conf

  • Filename
    181714