  • Title

    Diagnosis of aging degree of large hydrogenerator stator insulation

  • Author

    Renxiu, Liu ; Angen, Sun

  • Author_Institution
    Electr. Power Test Inst. of Gansu Province, Lanzhou City, China
  • fYear
    1991
  • fDate
    8-12 Jul 1991
  • Firstpage
    538
  • Abstract
    The variation of the electrical properties of 225 MW stator bars of a hydrogenerator which has run for about 15 years and the remaining service life of the bars with different deterioration in electrical properties have been investigated. Methods of diagnosing deterioration which are convenient to use on site are evaluated. The characteristic curves of insulation in AC or DC conditions which have been obtained experimentally may be divided into three regions: the working region, the testing region, and the losing-effectiveness region. The deterioration degrees of the insulation could be judged by using these regions
  • Keywords
    ageing; hydroelectric generators; insulation testing; machine insulation; machine testing; stators; 225 MW; AC conditions; DC conditions; aging degree; electrical properties; large hydrogenerator; on site diagnostic methods; stator bars; stator insulation; Aging; Breakdown voltage; Cities and towns; Current measurement; Hafnium; Insulation; Marine vehicles; Stator bars; Sun; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Properties and Applications of Dielectric Materials, 1991., Proceedings of the 3rd International Conference on
  • Conference_Location
    Tokyo
  • Print_ISBN
    0-87942-568-7
  • Type

    conf

  • DOI
    10.1109/ICPADM.1991.172116
  • Filename
    172116