  • Abstract
    A micro-channel plate (MCP) was used to measure the minute emission current within the range of 1×10-19 A to 1×10-14 A in a high vacuum (1.3×10-5 Pa). By a Fowler-Nordheim plot, it is found that the effective field strength for initial electron emission is mostly constant between 107 and 108 V/cm under any gap length. The effective field strength is held constant between 107 and 10 8 V/cm, independent of the current under any gap length. With this result, a model which shows the choice of minute projection is suggested. In order to certify this model, an MCP phosphor-anode is used. As a result, it is found that the minute projections which emit electrons melt with heat and are chosen when the voltage rises
  • Keywords
    electric current measurement; electron field emission; image intensifiers; 1.3E-5 Pa; 1E-19 to 1E-14 A; Fowler-Nordheim plot; MCP phosphor-anode; effective field strength; emission current; gap length; initial electron emission; micro-channel plate; minute projections; Assembly; Brightness; Cathodes; Current measurement; Electric variables measurement; Electrodes; Electron emission; Iron; Vacuum technology; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Properties and Applications of Dielectric Materials, 1991., Proceedings of the 3rd International Conference on
  • Conference_Location
    Tokyo
  • Print_ISBN
    0-87942-568-7
  • Type

    conf

  • DOI
    10.1109/ICPADM.1991.172194
  • Filename
    172194