• DocumentCode
    279535
  • Title

    Immunity control of communication receivers: selection of test effect

  • Author

    Boronichev, G.K.

  • Author_Institution
    Radio Res. Inst., Leningrad
  • fYear
    1992
  • fDate
    21-24 Sep 1992
  • Firstpage
    58
  • Lastpage
    59
  • Abstract
    The influence of test effect parameters on the accuracy of immunity parameters testing of VHF and UHF communication receivers is considered. It follows from the analysis that Publication 20 CISPR can be used for establishing appropriate test procedures. But, the introduction of some additional requirements to the test effect will be necessary, namely: the stability of its frequency and the correlation between the frequencies of the wanted input signal and the test effect. In this case, as in Publication 20 CISPR, it is possible to use AM oscillation as the test effect for receivers of FM and PM signals. For receivers of SSB signals modulation of the test effect is not required
  • Keywords
    electric variables measurement; electromagnetic compatibility; electronic equipment testing; modulation; radio receivers; AM oscillation; EMC; FM signals; PM signals; Publication 20 CISPR; SSB signals; UHF; VHF; correlation; frequency stability; immunity parameters; radio receivers; test effect parameters; test procedures; wanted input signal;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Electromagnetic Compatibility, 1992., Eighth International Conference on
  • Conference_Location
    Edinburgh
  • Print_ISBN
    0-85296-554-0
  • Type

    conf

  • Filename
    187198