DocumentCode
2798926
Title
A new concept for online surge testing for the detection of winding insulation deterioration
Author
Grubic, Stefan ; Habetler, Thomas G. ; Restrepo, Jose
Author_Institution
Sch. of Electr. & Comput. Eng., Georgia Inst. of Technol., Atlanta, GA, USA
fYear
2010
fDate
12-16 Sept. 2010
Firstpage
2747
Lastpage
2754
Abstract
A breakdown of the electrical insulation system causes catastrophic failure of the electrical machine and brings large process downtime losses. Preventive maintenance and online monitoring are some of the methods to improve reliability and reduce unscheduled downtime. One of the main reasons for failure is the breakdown of the stator insulation. The offline surge test is the most commonly used offline test to assess the condition of the turn insulation. There is no online monitoring method that is applicable to low voltage machines and has the same capabilities as the surge test. This paper introduces new concepts to implement an online surge test. The possibilities and limitations of the online surge test are presented as well as simulation and experimental results to validate the concepts.
Keywords
condition monitoring; failure analysis; insulation testing; machine insulation; machine windings; nondestructive testing; preventive maintenance; surges; condition monitoring; electrical insulation system breakdown; electrical machine failure; online monitoring; online surge testing; preventive maintenance; reliability; stator insulation; winding insulation deterioration detection; Impedance; Inductance; Inductors; Insulation; Surges; Torque; Transient analysis;
fLanguage
English
Publisher
ieee
Conference_Titel
Energy Conversion Congress and Exposition (ECCE), 2010 IEEE
Conference_Location
Atlanta, GA
Print_ISBN
978-1-4244-5286-6
Electronic_ISBN
978-1-4244-5287-3
Type
conf
DOI
10.1109/ECCE.2010.5618067
Filename
5618067
Link To Document