• DocumentCode
    2827257
  • Title

    Energy-Saving Analysis for a 600MW Coal-Fired Supercritical Power Plant

  • Author

    Yang Zhiping ; Wang Ningling ; Yang Yongping

  • Author_Institution
    Key Lab. of Condition Monitoring & Control for Power Plant Equip., MOE North China Electr. Power Univ., Beijing, China
  • fYear
    2009
  • fDate
    11-13 Dec. 2009
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    This paper mainly studies the energy-saving potential of a 600 MW coal-fired supercritical power plant using the energy-loss analysis method. Main factors in the boiler and turbines such as the main steam temperature and pressure, the turbine cylinder efficiency, the condenser pressure and so on are taken as the variables to analyze the system´s thermal and coal consumption rates. In addition, the real operation data at the loads of 75% and 50% are analyzed to trace the added thermal and coal consumptions. These results indicate the energy-saving direction for the system. The analyzing method can also be applied to other power generating systems to analyze the energy loss distributions.
  • Keywords
    boilers; coal gasification; power plants; turbines; boiler; coal consumption rates; coal fired supercritical power plant; energy loss analysis; energy saving potential; power 600 MW; power generating systems; thermal consumption rates; turbine cylinder; Boilers; Condition monitoring; Energy consumption; Energy loss; Laboratories; Power generation; Temperature; Thermal factors; Thermal loading; Turbines;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computational Intelligence and Software Engineering, 2009. CiSE 2009. International Conference on
  • Conference_Location
    Wuhan
  • Print_ISBN
    978-1-4244-4507-3
  • Electronic_ISBN
    978-1-4244-4507-3
  • Type

    conf

  • DOI
    10.1109/CISE.2009.5363921
  • Filename
    5363921