• DocumentCode
    283897
  • Title

    Oscillators to maintain precise time and frequency-an overview

  • Author

    Steele, J.McA.

  • Author_Institution
    NPL, Teddington, UK
  • fYear
    1992
  • fDate
    33919
  • Firstpage
    42370
  • Lastpage
    42373
  • Abstract
    Gives a broad indication of the relative stabilities of time and frequency devices available for use in the microwave region, and also their relative susceptibilities to environmental effects. The devices examined include quartz crystal oscillators, the caesium beam standard, the rubidium gas cell, and the hydrogen maser
  • Keywords
    caesium; crystal resonators; frequency stability; hydrogen; masers; measurement standards; microwave oscillators; quartz; rubidium; time measurement; Cs; H2; Rb; automatic standards; caesium beam standard; environmental effects; hydrogen maser; microwave region; quartz crystal oscillators; rubidium gas cell;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Precise Time and Frequency - the Beat of a Single Drum, IEE Colloquium on
  • Conference_Location
    London
  • Type

    conf

  • Filename
    214356