Abstract
The performance of two VLG-12 masers that have operated at the US Naval Observatory is described. The effectiveness of the single-state selection system and of the storage bulb coatings is discussed. Among other results, it is shown that the masers´ initial frequency drift rates of several parts in 1015 per day decreased by factors of 2 to 4 over a period of 200 days
Keywords
frequency measurement; hydrogen neutral atoms; masers; measurement standards; US Naval Observatory; VLG-12 masers; frequency drift rates; frequency measurement standard; single-state selection; storage bulb coatings; Atomic beams; Atomic measurements; Digital control; Frequency synthesizers; Hydrogen; Masers; Observatories; Seals; Vacuum systems; Vacuum technology;