Abstract
The problems which occur in synchronization of digital telecommunication networks are described. The architecture of the FTS 3800 timing signal generator is described. The 3800 has been designed to respond to some of the problems with existing synchronization equipment. Details of the design and performance are presented
Keywords
digital communication systems; measurement standards; redundancy; signal generators; synchronisation; timing circuits; FTS 3800 timing signal generator; architecture; digital telecommunication network synchronization; measurement standard; redundant timing source; Clocks; Communication industry; Computer buffers; Data communication; Digital systems; Frequency synchronization; Signal generators; Telecommunication standards; Telephony; Timing;