DocumentCode
2842803
Title
Frequency adjustment of the millimetric wave DR and its application in the Ka band DRO
Author
Hou-Changgan
Author_Institution
Inst. No.25, Acad. Sinica, Beijing, China
fYear
1998
fDate
1998
Firstpage
150
Lastpage
153
Abstract
In this paper is given an experiment test method to observe and adjust the millimetric wave DR (dielectric resonator) resonant frequency. The method is simple and audio-visual. By use of this method, the resonant frequency of the DR in a DRO (dielectric resonator oscillator) microstrip circuit is adjusted and fixed to the necessary frequency. As a result, the pragmatic design of the millimetric wave DRO engineering became simple and direct. In this paper is given the design method and a well-adjusted DRO: its center frequency is 31.0 GHz. In the temperature range of -40°C+50°C, the frequency stability may reach 15 ppm/°C. The DRO has extensive application prospects in use as a frequency converter pump source, transmitting exciting stage and LO in a millimetric wave seeker
Keywords
Gunn oscillators; dielectric resonator oscillators; dielectric resonators; frequency stability; microstrip circuits; microwave integrated circuits; millimetre wave devices; millimetre wave measurement; millimetre wave oscillators; test equipment; -40 to 50 C; 31 GHz; DR resonant frequency; DRO microstrip circuit; EHF; Ka-band DRO; LO; MIC; MM-wave DR; design method; dielectric resonator; dielectric resonator oscillator; frequency adjustment; frequency converter pump source; test method; transmitting exciting stage; Circuit testing; Design engineering; Design methodology; Dielectrics; Microstrip resonators; Oscillators; RLC circuits; Resonant frequency; Stability; Temperature distribution;
fLanguage
English
Publisher
ieee
Conference_Titel
Microwave and Millimeter Wave Technology Proceedings, 1998. ICMMT '98. 1998 International Conference on
Conference_Location
Beijing
Print_ISBN
0-7803-4308-5
Type
conf
DOI
10.1109/ICMMT.1998.768250
Filename
768250
Link To Document