• DocumentCode
    2843700
  • Title

    Life evaluation of a 35 KV submarine power cable in a continuous flexing environment

  • Author

    Pieroni, Charles A. ; Fellows, B.

  • Author_Institution
    Simplex Wire and Cable Company, Portsmouth, NH, USA
  • fYear
    1977
  • fDate
    17-19 Oct. 1977
  • Firstpage
    296
  • Lastpage
    303
  • Abstract
    This paper describes the life-testing of a 35 KV power cable that will connect a Single Anchor Leg Mooring (SALM) buoy with a platform in several hundred feet of water. While there are many power cable installations to offshore platforms, and between platforms, this system is unique because the cable will be constantly flexing in compression as the mooring buoy moves in the water. The buoy design includes an articulated leg, with universal joints, to which the cable is clamped. It is the loop in the cable where it crosses a universal joint that is flexed, and is a major cause of concern. To predict the effects of this constant flexure while energized, a flex simulator and electrical circuit was devised to duplicate the service environment as closely as possible. This paper describes the cable system, the test apparatus and procedure, and the results obtained.
  • Keywords
    Cable shielding; Conductors; Copper; Fabrics; Insulation; Leg; Power cables; Sea floor; Sea surface; Steel;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    OCEANS '77 Conference Record
  • Conference_Location
    Los Angeles, CA, USA
  • Type

    conf

  • DOI
    10.1109/OCEANS.1977.1154454
  • Filename
    1154454