Abstract
In this paper, single-phase shunt active power filter (APF) controlled through hysteresis-current control is studied. A proposition is made to use the limitation on the maximum switching frequency of the power devices. This limitation increases stability to electromagnetic influences and facilitates filtering of the radio interference to the source network. In the paper, there are attached computer simulations´ results and experimental oscilogrammes from the filter operation together with a combination of loads -linear (active inductive) and non-linear (single-phase bridge uncontrolled rectifier with capacitive load). The APF´s control is based on DSP TMS320LF2407.
Keywords
active filters; digital signal processing chips; electric current control; electromagnetic compatibility; hysteresis; power filters; DSP; active inductive loads; electromagnetic influences; frequency limitation; hysteresis current control; maximum switching frequency; oscilogrammes; radio interference; single-phase bridge uncontrolled rectifier; single-phase shunt active power filter; source network; Active filters; Bridges; Computer simulation; Current control; Electromagnetic interference; Filtering; Hysteresis; Rectifiers; Stability; Switching frequency; DSP; hysteresis-current control; single-phase shunt active power filter; switching frequency;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Conversion Conference - Nagoya, 2007. PCC '07
Conference_Location
Nagoya
Print_ISBN
1-4244-0844-X
Electronic_ISBN
1-4244-0844-X
Type
conf
DOI
10.1109/PCCON.2007.372954
Filename
4239144
Link To Document