• DocumentCode
    2849948
  • Title

    Power amplifier for high frequency CO2-laser stimulation

  • Author

    Vasil´ev, V.V. ; Shurygin, E.S.

  • Author_Institution
    Novosibirsk State Univ., Russia
  • fYear
    1998
  • fDate
    1998
  • Firstpage
    288
  • Lastpage
    291
  • Abstract
    We give the results of construction of the double-ended power amplifier on the generator tetrodes, which is used for the high frequency CO2-laser stimulation. The stimulation power approaches 3 kW in pulse and 500 W in the continuous mode, with the operation frequency of 110 MHz. A special attention is given to the effect of interaction of the active elements of the double-ended amplifier with the reflecting load, and to the choice of their operation mode
  • Keywords
    carbon compounds; gas lasers; laser accessories; power amplifiers; 110 MHz; 3 kW; 500 W; CO2; CO2-laser stimulation; active elements; continuous mode; double-ended amplifier; double-ended power amplifier; generator tetrodes; high frequency stimulation; interaction; operation frequency; operation mode; power amplifier; reflecting load; Anodes; Bridge circuits; Capacitors; Coupling circuits; Filters; Frequency; High power amplifiers; Lamps; Power lasers; Power supplies;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electronic Instrument Engineering Proceedings, 1998. APEIE-98. Volume 1. 4th International Conference on Actual Problems of
  • Conference_Location
    Novosibirsk
  • Print_ISBN
    0-7803-4938-5
  • Type

    conf

  • DOI
    10.1109/APEIE.1998.768967
  • Filename
    768967