DocumentCode
2859343
Title
Beam diffusion measurements at RHIC
Author
Fliller, R.P. ; Drees, A. ; Gassner, D. ; McIntyre, G. ; Peggs, S. ; Trbojevic, D.
Author_Institution
Brookhaven Nat. Lab., Upton, NY, USA
Volume
5
fYear
2003
fDate
12-16 May 2003
Firstpage
2904
Abstract
During a store, particles from the beam core continually diffuse outwards into the halo through a variety of mechanisms. Understanding the diffusion rate as a function of particle amplitude can help discover which processes are important to halo growth. A collimator can be used to measure the amplitude growth rate as a function of the particle amplitude. In this paper we present results of diffusion measurements performed at the Relativistic Heavy Ion Collider (RHIC) with fully stripped gold ions, deuterons, and protons. We compare these results with measurements from previous years, and simulations, and discuss any factors that relate to beam growth in RHIC.
Keywords
colliding beam accelerators; collimators; ion accelerators; particle beam diagnostics; particle beam dynamics; proton accelerators; storage rings; synchrotrons; RHIC; Relativistic Heavy Ion Collider; amplitude growth rate; beam core; beam diffusion measurements; collimator; deuterons; fully stripped ions; gold ions; halo growth; particle amplitude; particle storage; protons; Clocks; Collimators; Current measurement; Gold; Ion accelerators; Particle beam measurements; Particle beams; Performance evaluation; Protons; Superconducting magnets;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 2003. PAC 2003. Proceedings of the
Conference_Location
Portland, OR
ISSN
1063-3928
Print_ISBN
0-7803-7738-9
Type
conf
DOI
10.1109/PAC.2003.1289761
Filename
1289761
Link To Document