  • Abstract
    Microwave cavity is the core part to the physics package of hydrogen maser. The most suitable mode to achieve hydrogen maser self-oscillation was considered and dimensions of the cavity with 1.42G cavity frequency in TE011mode were calculated. The calculated result of the cavity was confirmed by FEM simulation. Then the factors which may affect the stability of Hydrogen maser were analysed. Finally, the maser oscillation signal was obtained and the stability of the signal was tested.
  • Keywords
    finite element analysis; hydrogen; masers; microwave devices; oscillations; FEM simulation; TE011mode; active hydrogen maser; cavity frequency; hydrogen maser self-oscillation; maser oscillation signal; microwave cavity design; physics package; signal stability; Atomic clocks; Cavity resonators; Hydrogen; Masers; Microwave oscillators; Stability analysis; Hydrogen atomic maser; cylindrical cavity; microwave cavity; mode;