• DocumentCode
    2869421
  • Title

    Error Analysis of High-moisture Maize Moisture Measurement with PM-8188 Grain Moisture Tester

  • Author

    Hao-cheng, He ; Shao-ming, Li ; Zhe, Liu ; Hu, Wang ; Dong, An ; Xiao-dong, Zhang ; De-hai, Zhu ; Chang-qing, Bai

  • Author_Institution
    Coll. of Inf. & Electr. Eng., China Agric. Univ., Beijing, China
  • fYear
    2011
  • fDate
    21-23 Oct. 2011
  • Firstpage
    1
  • Lastpage
    3
  • Abstract
    PM-8188 type capacitance grain moisture tester was used to detect the moisture of twenty-four maize hybrids in the period of harvest time and the period when the grain were naturally fully dehydrated, the results were compared with the results of grain weight change, and the changes of measurement errors in high moisture levels were discussed briefly. The results showed that the measurement error reached its minimum by the measured value of 26.2. The measured value was larger than the true value when below 26.2, but smaller when exceeded. And the measurement error increased with the deviation from 26.2.
  • Keywords
    crops; error analysis; moisture measurement; test equipment; PM-8188 type capacitance grain moisture tester; error analysis; high-moisture maize moisture measurement; measurement error; Capacitance; Measurement errors; Measurement uncertainty; Moisture; Moisture measurement; Time measurement; Weight measurement; grain moisture tester; maize; measurement error; moisture;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation, Measurement, Computer, Communication and Control, 2011 First International Conference on
  • Conference_Location
    Beijing
  • Print_ISBN
    978-0-7695-4519-6
  • Type

    conf

  • DOI
    10.1109/IMCCC.2011.9
  • Filename
    6119179