• DocumentCode
    2878202
  • Title

    Advanced scanning acoustic technique application in flip-chip devices

  • Author

    Hu, X.H. ; Tay, M.Y. ; Tan, M.C. ; Zhao, X.L. ; Chin, J.M. ; Lei, H.

  • Author_Institution
    Device Anal. Lab., Adv. Micro Devices (Singapore) Pte Ltd., Singapore, Singapore
  • fYear
    2011
  • fDate
    4-7 July 2011
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    Micron-size embedded defects are challenging to detect using the traditional acoustic scanning microscope. This paper presents the latest acoustic techniques using Virtual Rescanning Mode™ (VRM) from Sonoscan® to successfully capture the defects localized at inter-layer dielectrics (ILD). Defects between copper trace and solder mask are more clearly seen when the magnitude of acoustic waveform changes from time domain to frequency domain.
  • Keywords
    acoustic imaging; copper alloys; flip-chip devices; solders; acoustic waveform; copper trace; flip-chip devices; frequency domain; interlayer dielectrics; micronsize embedded defects; scanning acoustic technique; solder mask; time domain; virtual rescanning mode; Acoustics; Copper; Delamination; Frequency domain analysis; Substrates; Time domain analysis; Transducers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Physical and Failure Analysis of Integrated Circuits (IPFA), 2011 18th IEEE International Symposium on the
  • Conference_Location
    Incheon
  • ISSN
    1946-1542
  • Print_ISBN
    978-1-4577-0159-7
  • Electronic_ISBN
    1946-1542
  • Type

    conf

  • DOI
    10.1109/IPFA.2011.5992791
  • Filename
    5992791