DocumentCode
2881084
Title
Harmful electromagnetic effect on affected line from disturbing line
Author
Dan, Shi ; Yougang, Gao ; Yuanmao, Shen
Author_Institution
Sch. of Telecommun. Eng., Beijing Univ. of Posts & Telecommun.
fYear
2006
fDate
1-4 Aug. 2006
Firstpage
714
Lastpage
719
Abstract
When two transmission lines are parallel, one line will disturb another due to inductive and capacitive coupling. This paper presents precise formulas for calculating interference in symbolic form. It illustrates relationship between interference and mutual inductance, capacitance, impedance, attenuation, parallel length clearly. Some new work has been done. One most common situation is considered, in which two lines parallel have attenuation and their length are not equal. In addition, some important cases are used to verify the solution
Keywords
electromagnetic interference; transmission line theory; affected line; attenuation; capacitance; disturbing line; harmful electromagnetic effect; impedance; interference; mutual inductance; Attenuation; Distributed parameter circuits; Electromagnetic coupling; Inductance; Interference; Magnetic analysis; Pipelines; Power transmission lines; Transmission lines; Voltage; capacitive coupling; inductive coupling; interference; transmission lines;
fLanguage
English
Publisher
ieee
Conference_Titel
Environmental Electromagnetics, The 2006 4th Asia-Pacific Conference on
Conference_Location
Dalian
Print_ISBN
1-4244-0183-6
Type
conf
DOI
10.1109/CEEM.2006.258054
Filename
4027386