• DocumentCode
    2885175
  • Title

    Thermal analysis of cantilever MEMS based Low power microheater array for the selective detection of explosive and toxic gases

  • Author

    Ghosh, Sugato ; Chatterjee, Sayan ; Kundu, Avra ; Maity, Santanu ; Saha, Hiranmay

  • Author_Institution
    Dept. of Electronics and Telecommunication Engineering, Jadavpur University, Kolkata 700032, India
  • fYear
    2012
  • fDate
    7-10 March 2012
  • Firstpage
    290
  • Lastpage
    293
  • Abstract
    A cantilever type microheater array consisting of four individual isolated microheaters on single die has been designed here for MEMS based gas sensor platform using metal oxide semiconductor for different gas detection through a single sensor die for explosive and toxic gas analysis in the underground manhole. A thin SiO2/Si3N4 cantilever of 250µn X 100µn has been designed here for low power consumption and uniform temperature distribution throughout the entire active area. As the microheaters are isolated from each other, different temperatures may be achieved by applying different voltages in different heaters.
  • Keywords
    MEMS cantilever; explosive and toxic gas; low power consumption; microheater array;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Physics and Technology of Sensors (ISPTS), 2012 1st International Symposium on
  • Conference_Location
    Pune, India
  • Print_ISBN
    978-1-4673-1040-6
  • Type

    conf

  • DOI
    10.1109/ISPTS.2012.6260949
  • Filename
    6260949