DocumentCode
2885444
Title
Improving the SIS18 performance by use of the Orbit Response Method
Author
Parfenova, A. ; Franchetti, G. ; Hofmann, I. ; Omet, C. ; Lee, S.Y.
Author_Institution
GSI, Darmstadt
fYear
2007
fDate
25-29 June 2007
Firstpage
3256
Lastpage
3258
Abstract
The GSI heavy ion synchrotron SIS 18 will be used as a booster for the new FAIR facility SIS 100. A well- controlled linear optics of the SIS 18 is necessary for further optimization studies of nonlinear dynamics, resonance induced beam loss, dynamic aperture and nonlinear error measurements. The analysis of the orbit response matrix (ORM) [1] is a powerful tool to calibrate the linear lattice models. We present results of orbit response analysis of several measurement campaigns on the SIS 18 and discuss the achieved improvement of the SIS 18 performance.
Keywords
booster injectors; ion accelerators; ion beams; optimisation; particle beam diagnostics; particle beam dynamics; synchrotrons; BPM; FAIR facility SIS 100; GSI heavy ion synchrotron; ORM; SIS 18; beam position monitors; booster injection; linear lattice models; linear optics; nonlinear dynamics; optimization studies; orbit response matrix; resonance induced beam loss; Apertures; Error correction; Extraterrestrial measurements; Loss measurement; Nonlinear optics; Optical control; Optical losses; Particle beam optics; Resonance; Synchrotrons;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 2007. PAC. IEEE
Conference_Location
Albuquerque, NM
Print_ISBN
978-1-4244-0916-7
Type
conf
DOI
10.1109/PAC.2007.4440390