DocumentCode
2895791
Title
Application of hamming windowed interpolated DFT algorithm based on modified ideal sampling frequency in on-line measuring dielectric loss angle
Author
Lijun, Qin ; Qing, Guo ; Cuijuan, Hao ; Huawei, Jin
Author_Institution
Dept. of Electr. & Electron. Eng., North China Electr. Power Univ., Beijing, China
fYear
2011
fDate
6-9 July 2011
Firstpage
1226
Lastpage
1231
Abstract
To assess the insulation condition of capacitive apparatus, on-line monitoring of dielectric loss angle is an effective measure. Harmonic analysis algorithm is used to calculate dielectric loss angle traditionally, this method can effectively suppress the DC (Direct Current) offset and harmonic interference. However, when the power system frequency fluctuates, the synchronous sampling condition is difficult to meet, so, traditional harmonic analysis method can produce leakage of spectrum and picket-fence effect, which greatly affects the accuracy of dielectric loss angle measurement. In order to reduce this adverse effect, this paper proposes a method called hamming windowed interpolated DFT (Discrete Fourier Transform) algorithm based on modified ideal sampling frequency. Time series analysis based on modified ideal sampling frequency can be used to modify the time series in non-synchronous sampling condition to meet synchronous sampling condition. Hamming windowed interpolated DFT algorithm can inhibit leakage of spectrum and picket-fence effect. Firstly this paper analyzes the principle of traditional DFT algorithm and the reason that causes leakage of spectrum and picket-fence effect in non-synchronous sampling condition. Secondly, the principle of hamming windowed interpolated DFT algorithm based on modified ideal sampling frequency is elaborated. Finally this paper presents the simulation result which shows that the improved approach has higher accuracy.
Keywords
dielectric loss measurement; dielectric losses; discrete Fourier transforms; harmonic analysis; interpolation; power system harmonics; sampling methods; DC offset; capacitive apparatus; dielectric loss angle measurement; discrete Fourier transform; hamming windowed interpolated DFT algorithm; harmonic analysis algorithm; harmonic interference; insulation condition; modified ideal sampling frequency; nonsynchronous sampling condition; online measuring dielectric loss angle; picket-fence effect; power system frequency; time series analysis; Dielectric loss measurement; Dielectrics; Discrete Fourier transforms; Frequency measurement; Harmonic analysis; Loss measurement; DFT; dielectric loss angle measurement; hamming windowed interpolated DFT algorithm; leakage of spectrum and picket-fence effect; modified ideal sampling frequency;
fLanguage
English
Publisher
ieee
Conference_Titel
Electric Utility Deregulation and Restructuring and Power Technologies (DRPT), 2011 4th International Conference on
Conference_Location
Weihai, Shandong
Print_ISBN
978-1-4577-0364-5
Type
conf
DOI
10.1109/DRPT.2011.5994082
Filename
5994082
Link To Document