DocumentCode
2907818
Title
Wind Energy Conversion Systems as active filters under unbalanced load conditions
Author
Todeschini, Grazia
fYear
2010
fDate
26-29 Sept. 2010
Firstpage
1
Lastpage
7
Abstract
The present paper investigates the performance of a Wind Energy Conversion System controlled to operate as an Active Filter when unbalanced loads are supplied by the same feeder. The control strategy named `compensation by means of Combined Modulation´ is applied. This control methodology has been designed to sink the harmonic currents injected by balanced Non-Linear Load, and the connection of unbalanced loads to the PCC results in additional harmonic current flows within the WECS components and other detrimental effects. This paper is intended to analyze these effects and to determine the unbalanced load conditions that can be withstood by the WECS without compromising the components´ integrity.
Keywords
active filters; power generation control; power harmonic filters; wind power plants; active filters; combined modulation; control methodology; harmonic current flows; unbalanced load conditions; wind energy conversion systems; Bridge circuits; Converters; Harmonic analysis; Modulation; Power system harmonics; Stator windings; Derating; Harmonic Compensation; Power Loss; Total Harmonic Distortion (THD); Unbalance; Wind Energy;
fLanguage
English
Publisher
ieee
Conference_Titel
Harmonics and Quality of Power (ICHQP), 2010 14th International Conference on
Conference_Location
Bergamo
Print_ISBN
978-1-4244-7244-4
Electronic_ISBN
978-1-4244-7245-1
Type
conf
DOI
10.1109/ICHQP.2010.5625458
Filename
5625458
Link To Document