• DocumentCode
    2907818
  • Title

    Wind Energy Conversion Systems as active filters under unbalanced load conditions

  • Author

    Todeschini, Grazia

  • fYear
    2010
  • fDate
    26-29 Sept. 2010
  • Firstpage
    1
  • Lastpage
    7
  • Abstract
    The present paper investigates the performance of a Wind Energy Conversion System controlled to operate as an Active Filter when unbalanced loads are supplied by the same feeder. The control strategy named `compensation by means of Combined Modulation´ is applied. This control methodology has been designed to sink the harmonic currents injected by balanced Non-Linear Load, and the connection of unbalanced loads to the PCC results in additional harmonic current flows within the WECS components and other detrimental effects. This paper is intended to analyze these effects and to determine the unbalanced load conditions that can be withstood by the WECS without compromising the components´ integrity.
  • Keywords
    active filters; power generation control; power harmonic filters; wind power plants; active filters; combined modulation; control methodology; harmonic current flows; unbalanced load conditions; wind energy conversion systems; Bridge circuits; Converters; Harmonic analysis; Modulation; Power system harmonics; Stator windings; Derating; Harmonic Compensation; Power Loss; Total Harmonic Distortion (THD); Unbalance; Wind Energy;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Harmonics and Quality of Power (ICHQP), 2010 14th International Conference on
  • Conference_Location
    Bergamo
  • Print_ISBN
    978-1-4244-7244-4
  • Electronic_ISBN
    978-1-4244-7245-1
  • Type

    conf

  • DOI
    10.1109/ICHQP.2010.5625458
  • Filename
    5625458