• DocumentCode
    2910213
  • Title

    A comparison between the TORUS and AFIR axial-flux permanent-magnet machine using finite element analysis

  • Author

    Mahmoudi, Amin ; Ping, Hew Wooi ; Rahim, Nasrudin Abdul

  • Author_Institution
    Fac. of Eng., Univ. of Malaya, Kuala Lumpur, Malaysia
  • fYear
    2011
  • fDate
    15-18 May 2011
  • Firstpage
    242
  • Lastpage
    247
  • Abstract
    This paper presents a comparison between TORUS and AFIR, the two topologies for double-sided axial-flux permanent-magnet machines. Their slotted and non-slotted topologies were investigated and compared in terms of power density and torque quality. The critical field analysis of the topologies was by finite element method. Results show TORUS topology´s high power-density in high current-density and low electrical-loading. AFIR topology has high power in low current-density and high electrical-loading. Non-slotted TORUS and AFIR AFPM machines have negligible cogging torque and lower ripple torque than their slotted counterparts.
  • Keywords
    finite element analysis; permanent magnet machines; rotors; stators; torque; AFIR; TORUS; cogging torque; critical field analysis; double-sided axial-flux permanent-magnet machines; finite element analysis; non-slotted topology; power density; ripple torque; slotted axial-flux one- stator-two-rotor topology; torque quality; two-stator-one-rotor topology; Air gaps; Magnetic flux; Rotors; Stator windings; Topology; Torque; axial-flux; permanent-magnet; slotless; slotted; wind generator;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electric Machines & Drives Conference (IEMDC), 2011 IEEE International
  • Conference_Location
    Niagara Falls, ON
  • Print_ISBN
    978-1-4577-0060-6
  • Type

    conf

  • DOI
    10.1109/IEMDC.2011.5994853
  • Filename
    5994853