DocumentCode
2922312
Title
Novel Process Control by Measurement of Silicon Lattice Damage
Author
Towner, Janet M. ; Lappan, Raymond E.
Author_Institution
AMI Semicond. Inc., Pocatello
fYear
2007
fDate
11-12 June 2007
Firstpage
34
Lastpage
38
Abstract
In this work, a novel SPC monitor of RTP temperature was developed where measurements are made directly on product. This technique significantly reduces test wafer costs while allowing real-time determination of functionality directly on the area of interest. The technique is useful over the entire operational range of the tool temperatures. However, in this latter cases reusable test wafers are needed since lower temperatures do not fully activate the implants.
Keywords
elemental semiconductors; materials testing; rapid thermal processing; silicon; rapid thermal processing temperature; reusable test wafer; silicon lattice damage measurement; statistical process control monitor; test wafer cost reduction; Annealing; Implants; Ion implantation; Lattices; Plasma temperature; Process control; Pump lasers; Silicon; Temperature measurement; Testing; Ion Implantation; RTP; SPC; Thermaprobe;
fLanguage
English
Publisher
ieee
Conference_Titel
Advanced Semiconductor Manufacturing Conference, 2007. ASMC 2007. IEEE/SEMI
Conference_Location
Stresa
Print_ISBN
1-4244-0652-8
Electronic_ISBN
1-4244-0653-6
Type
conf
DOI
10.1109/ASMC.2007.375076
Filename
4259242
Link To Document