DocumentCode
2924860
Title
Calibration method for four-terminal-pair capacitance standards: Progress report
Author
Aoki, T. ; Suzuki, K. ; Yokoi, K.
Author_Institution
Meas. Stand. Center, Hewlett-Packard Japan Ltd., Tokyo, Japan
fYear
1998
fDate
6-10 July 1998
Firstpage
36
Lastpage
37
Abstract
The paper titled "A New Universal Calibration Method for Four-Terminal-Pair Admittance Standards" (1991) described briefly a calibration method for commercially available four-terminal-pair capacitance standards (4TP C STDs). Since we established an accurate calibration method for the 4TP C STDs using a network analyzer and a 1 kHz capacitance bridge, this paper describes the method for a 1000 pF air dielectric 4TP C STD at 10 MHz.
Keywords
bridge instruments; calibration; capacitance measurement; measurement standards; network analysers; 1 kHz; 10 MHz; 1000 pF; air dielectric; calibration; capacitance bridge; four-terminal-pair capacitance standards; inductance; network analyzer; Admittance; Bridge circuits; Calibration; Capacitance; Electrical resistance measurement; Equations; Frequency measurement; Impedance measurement; Measurement standards; Q measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements Digest, 1998 Conference on
Conference_Location
Washington, DC, USA
Print_ISBN
0-7803-5018-9
Type
conf
DOI
10.1109/CPEM.1998.699747
Filename
699747