DocumentCode
2932812
Title
Final qualification of an industrial wide range neutron instrumentation in the OSIRIS MTR reactor
Author
Barbot, L. ; Normand, S. ; Pasdeloup, P. ; Lescop, B.
Author_Institution
Lab. Capteur et Archit. Electroniques, CEA, Gif-sur-Yvette, France
fYear
2009
fDate
7-10 June 2009
Firstpage
1
Lastpage
4
Abstract
This work deals with the final qualification of the IRINA in-core neutron flux measurement system in the MTR OSIRIS reactor. A specific irradiation device has been set up to validate the last changes in the complete system (electronic, transmitting cable and monitor). Experimental results shows the IRINA measurement system meet entirely the in-core reactor conditions requirements: a thermal neutron flux from 107 n.cm-2.s-1 up to 1014 n.cm-2.s-1 and a temperature of 300°C during a minimum operating time of 1000 hours.
Keywords
fission reactor core control; fission reactor design; fission reactor instrumentation; fission reactor theory; fission research reactors; neutron transport theory; IRINA in-core neutron flux measurement system; IRINA measurement system; OSIRIS MTR reactor; in-core condition; industrial wide range neutron instrumentation; operating time; temperature 300 degC; thermal neutron flux; transmission cable; Detectors; Electronics industry; Inductors; Industrial electronics; Instruments; Manufacturing; Monitoring; Neutrons; Qualifications; Reactor instrumentation; Fission Chamber; In-Core Neutron Measurements; MTR Reactor; Wide Range Instrumentation;
fLanguage
English
Publisher
ieee
Conference_Titel
Advancements in Nuclear Instrumentation Measurement Methods and their Applications (ANIMMA), 2009 First International Conference on
Conference_Location
Marseille
Print_ISBN
978-1-4244-5207-1
Electronic_ISBN
978-1-4244-5208-8
Type
conf
DOI
10.1109/ANIMMA.2009.5503828
Filename
5503828
Link To Document