Abstract
Paper deals with the practical application of newly developed stochastic watt-hour meter. The limit of its precision is analysed theoretically, via simulation, and experiments. The precision of 0.0062% is achieved in the laboratory experiment. Field experiment also confirms good application properties of the device
Keywords
watthour meters; measurement precision; stochastic watt-hour meter; Circuit simulation; Clocks; Energy measurement; Instruments; Laboratories; Logic circuits; Measurement errors; Power measurement; Stochastic processes; Threshold voltage;