DocumentCode
2953781
Title
The quantized Hall resistance standard at CMS
Author
Ku, Y.S. ; Hsu, C.M. ; Pang, H.L. ; Hsiao, J.C.
Author_Institution
Center for Meas. Stand., Taiwan, China
fYear
1998
fDate
6-10 July 1998
Firstpage
345
Lastpage
346
Abstract
We report on precision measurements of the quantum Hall resistance (QHR) in Center for Measurement Standards (CMS) for primary resistance standard establishment. The standard reproduces points of R/sub H/(i=2) and R/sub H/(i=4) with relative uncertainties, given as one-standard-deviation estimates, of 6/spl times/10/sup -9/.
Keywords
electric resistance measurement; measurement standards; quantum Hall effect; CMS; quantized Hall resistance standard; Bridges; Collision mitigation; Current measurement; Electrical resistance measurement; Magnetic field measurement; Measurement standards; Resistors; SQUIDs; Superconducting magnets; Temperature sensors;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements Digest, 1998 Conference on
Conference_Location
Washington, DC, USA
Print_ISBN
0-7803-5018-9
Type
conf
DOI
10.1109/CPEM.1998.699943
Filename
699943