DocumentCode
2956747
Title
Measurement system for the voltage dependence of high voltage AC-DC thermal converters
Author
Pogliano, U. ; Bosco, G.C. ; D´Elia, V.
Author_Institution
Ist. Elettrotecnico Nazionale Galileo Ferraris, Torino, Italy
fYear
1998
fDate
6-10 July 1998
Firstpage
377
Lastpage
378
Abstract
A new system for the measurement of the voltage dependence of range resistors for high voltage AC-DC thermal converters, which uses high voltage capacitors as reference, has been set up. Preliminary results of the comparison between range resistors and commercial capacitors are reported and the design of specific high voltage capacitors is described.
Keywords
capacitors; convertors; high-voltage techniques; measurement systems; measurement uncertainty; resistors; transfer standards; voltage measurement; AC-DC thermal converters; high voltage reference capacitors; measurement system; range resistors; step-up procedure; traceability; transfer difference; uncertainty; voltage dependence; Analog-digital conversion; Capacitors; Electrical resistance measurement; Impedance; Laboratories; Resistors; Thermal resistance; Thermoelectricity; Voltage measurement; Voltmeters;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements Digest, 1998 Conference on
Conference_Location
Washington, DC, USA
Print_ISBN
0-7803-5018-9
Type
conf
DOI
10.1109/CPEM.1998.699959
Filename
699959