• DocumentCode
    2957221
  • Title

    Effect of strain rate on fatigue of low-tin lead-base solder

  • Author

    Vaynman, Semyon

  • Author_Institution
    Basic Ind. Res. Lab., Northwestern Univ., Evanston, IL, USA
  • fYear
    1989
  • fDate
    22-24 May 1989
  • Firstpage
    273
  • Lastpage
    276
  • Abstract
    A study of fatigue of low-tin lead-base solder at different strain rates is discussed. The effect of tensile hold time (low strain rate) in reducing the number of cycles to failure was found to be much greater than the effect of ramp time (higher strain rate). While increase up to 1 h time per cycle for no-hold tests did not lead to fatigue life saturation, increase in tensile hold time over a few minutes led to saturation in the number of cycles to failure. Differences in the effects of hold and ramp were attributed to different mechanisms of solder fatigue fracture. It was concluded that fatigue life prediction of solder should be based on tests involving hold time
  • Keywords
    deformation; fatigue testing; lead alloys; soldering; stress relaxation; tin alloys; PbSn; alloys; cycles to failure; fatigue life saturation; hold time; low-tin lead-base solder; materials testing; no-hold tests; ramp time; solder fatigue fracture; strain rate; tensile hold time; Capacitive sensors; Failure analysis; Fatigue; Frequency; Lead; Life testing; Soldering; Temperature; Tensile strain; Tensile stress;