DocumentCode
2965448
Title
Intercomparison of a 10 mH inductance standard between UME-PTB
Author
Gulmez, Y. ; Turhan, E. ; Gulmez, G. ; Eckardt, H. ; Rather, P.
Author_Institution
Ulusal Metroloji Enstitusu, Kocaeli, Turkey
fYear
1998
fDate
6-10 July 1998
Firstpage
498
Lastpage
499
Abstract
Turkish and German Metrology Institutes (UME and PTB) performed an intercomparison of 10 mH inductance standards at 1 kHz. The measurements of the thermostatically-controlled transfer standard of PTB were taken by new Maxwell-Wien bridge with a Wagner arm made in UME. Relative difference of UME and PTB measurements on the same standard was found to be 5.10/sup -6/. Results have shown that this type of Maxwell-Wien bridge is capable of producing very precise measurements on standard inductors and promised further developments that will increase the accuracy of the system.
Keywords
bridge circuits; calibration; inductance measurement; inductors; transfer standards; Maxwell-Wien bridge; UME-PTB intercomparison; Wagner arm; inductance standards; international intercomparison; precise measurements; relative differences; standard inductors; thermostatically-controlled transfer standard; traceability; zero substitution method; Bridge circuits; Capacitance; Capacitors; Electrical resistance measurement; Inductance measurement; Inductors; Measurement standards; Resistors; Standards development; Temperature;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements Digest, 1998 Conference on
Conference_Location
Washington, DC, USA
Print_ISBN
0-7803-5018-9
Type
conf
DOI
10.1109/CPEM.1998.700024
Filename
700024
Link To Document